Description
![]()
ADVANCE Electronic Fluorescent Ballast, Universal 120V-277V Input, one or two F96T12, F96T12ES, F72T12 Lamps, Instant Start
Advance Centium ICN-2P60-N (ICN-2P60-SC) Electronic Fluorescent Ballast Guide
Quick Answer: The Advance Centium ICN-2P60-N (historically cross-referenced as ICN-2P60-SC; Signify / Philips Advance) is a high-performance commercial electronic fluorescent ballast engineered to operate 1 or 2 8-foot (96-inch) Slimline instant-start lamps (such as F96T12 60W or 75W, and energy-saving F96T12/ES 60W) as well as 8-foot linear T8 Slimline lamps (F96T8 59W) on universal 120–277V line voltage. Featuring Instant Start parallel ignition, IntelliVolt auto-voltage sensing, a normal 0.88 Ballast Factor, and a low-profile compact N-Can housing, it is the primary electronic energy-saving replacement for obsolete magnetic 8-foot slimline ballasts.
Advance Centium ICN-2P60-N Overview & Key Features
The Advance Centium ICN-2P60-N commercial ballast offers significant wattage reduction, instant start operation, and dependable performance when retrofitting 8-foot fluorescent fixtures:
- Legacy Magnetic 8-Foot Retrofit: Designed as the direct high-efficiency solid-state upgrade for older magnetic core-and-coil ballasts, reducing system power draw and eliminating 60 Hz hum.
- Instant Start Parallel Operation: Features instant arc ignition with independent parallel lamp circuitry, ensuring that if one lamp fails, the remaining lamp remains fully illuminated.
- IntelliVolt Universal Voltage: Senses and operates smoothly across AC line inputs from 120V to 277V at 50/60 Hz without requiring manual tap changes.
- N-Can Low-Profile Enclosure: Housed in a standard 9.5-inch compact metal case designed to fit effortlessly into narrow industrial channels and commercial strip wireways.
- High Electrical Quality: Commercial power quality with a high power factor (>0.98) and Total Harmonic Distortion (THD) under 10%.
Advance Centium ICN-2P60-N Technical Specifications
Core performance specifications and electrical ratings for the Advance Centium ICN-2P60-N ballast:
| Specification Parameter | Rating / Value | Details & Performance Standards |
|---|---|---|
| Input Voltage | 120 – 277 VAC | IntelliVolt auto-sensing supply, 50/60 Hz |
| Lamp Compatibility | F96T12 (75W), F96T12/ES (60W), F72T12 | 8-ft and 6-ft single-pin slimline fluorescent lamps |
| Number of Lamps | 1 or 2 Lamps | Operates 1 or 2 slimline instant-start lamps |
| Starting Method | Instant Start | Independent parallel lamp circuit ignition |
| Ballast Factor | 0.88 (Normal Ballast Factor) | Standard light output profile for commercial spaces |
| Power Factor / THD | > 0.98 PF / < 10% THD | Commercial grade high power factor performance |
| Starting Temperature | 0°F (-18°C) std / 60°F (16°C) ES | Cold-start capability for indoor and protected fixtures |
| Enclosure Type | N-Can Metal Housing | Compact housing (9.5" L x 1.3" W x 1.0" H) |
| Sound Rating | Class A | Quiet electronic operation for quiet commercial interiors |
| Compliance & Certifications | UL Listed, CSA Certified | RoHS compliant, Class P thermally protected |
Installation & Wiring Guidelines
- Power Disconnect: Always shut off main AC electrical power at the circuit breaker panel prior to servicing or installing the ballast.
- Instant Start Parallel Wiring: Wire the line leads (Black/Line, White/Neutral) and output lamp leads following the diagram on the ballast label. With parallel circuitry, one burned-out lamp will not extinguish the other lamp.
- Enclosure Grounding & Heat Dissipation: Securely fasten the metal N-Can housing to the grounded metal fixture enclosure for safe electrical grounding and direct thermal heat dissipation.
Frequently Asked Questions
What does "ICN-2P60-N" stand for in Advance's catalog?
"I" designates IntelliVolt (120–277V), "CN" indicates the Centium series, "2" represents 2-lamp maximum capacity, "P" stands for Premium Instant Start, "60" designates 60W slimline lamps, and "N" denotes the N-Can enclosure style.
What is the relationship between ICN-2P60-N and ICN-2P60-SC?
The ICN-2P60-SC was the earlier Small Can (SC) version of this ballast. Advance updated the housing profile to the modernized N-Can designator (ICN-2P60-N), maintaining identical electrical parameters and mounting hole configurations.
What is the difference between ICN-2P60-N and ICN-2S110-SC?
The ICN-2P60-N operates 8-foot single-pin Slimline lamps (F96T12 60W/75W, F72T12 57W) via Instant Start parallel circuitry, whereas the ICN-2S110-SC operates 8-foot High-Output (HO) recessed double-contact lamps (F96T12/HO 110W) via Rapid Start series circuitry.
- Advance Philips Discontinued R-2S110-TP, ICN-2P60-SC, R-2E75-S-TP, R-2E60-S-TP
- Universal B260IUNVHP, 806-SLH-TC-P, 827-SLH-TC-P
- GE GE260IS-MV-N (74474), GEN296IS120, GEN296IS277
- OSRAM MB2X96/120IS, MB2X96/277IS
Spec Sheets
Download the official manufacturer documentation and specifications:
Additional Information
Our Part No: |
BSF-ICN2P60N |
Mfr Part #: |
ICN2P60N |
Manufacturer Material Code: |
913701261901, 913701261902 |
Brand: |
Advance |
Fixture Type: |
Electronic Fluorescent |
Input Voltage: |
120-277V (Universal) |
Lamp: |
(1/2) F96T12, (1/2) F96T12/ES, (1/2) F72T12 |
Dimensions: |
9.5" (L) x 1.3"(W) x 1.0" (H) |
Product Data Sheet: |
See PDF Link Provided |
Start Method: |
Instant Start |
Alternative Keywords: |
ICN-2P60-SC, ICN2P60N35I, ICN2P60N35M |
Number Of Lamps: |
1, 2 |
Operates: |
F96T12, F96T12ES, F72T12 |
Warranty: |
Manufacturer's |
Case Size: |
10 |